When it comes to protecting a building—and everyone inside—fire alarm systems are your first line of defense. But even the best fire panels, smoke detectors, and notification appliances are only as reliable as the cable connecting them all. That’s where the 18/2 Fire Alarm Riser Cable comes into play.
Let’s break down what this cable is, why it matters, and why it’s particularly well-suited for commercial applications.
“18/2” stands for two conductors (wires) each of 18-gauge thickness. This type of cable is specifically designed for fire alarm systems, intercoms, security systems, and similar low-voltage installations. The “riser” part refers to its ability to be safely installed in vertical shafts or between floors in a commercial building, without spreading flames between levels in the event of a fire.
Here’s what defines an 18/2 Fire Alarm Riser Cable and makes it tick:
Gauge: 18 AWG (American Wire Gauge), thick enough for durability and signal integrity, but thin enough for flexibility and ease of routing.
Conductors: Two—typically solid bare copper for consistent electrical performance.
Insulation: PVC or other flame-retardant material.
Jacket Rating: Riser-rated (CL3R/CMR), which meets NEC requirements for vertical installations.
Voltage Rating: Usually rated for up to 300 volts.
Temperature Rating: Commonly rated for up to 75°C (167°F).
Let’s get into the specifics of why 18/2 riser cable is such a solid fit for fire safety infrastructure in commercial buildings.
Commercial systems have to follow strict National Electrical Code (NEC) guidelines. The 18/2 Riser Cable with its CL3R or FPLR rating checks all the boxes without going overboard.
Need to install it between floors? Riser-rated cable is literally made for that. No need to spend extra on plenum cable (which is for air ducts) unless your install environment demands it.
When you’re running cables across multiple stories of an office building or hospital, voltage drops and interference can be a problem. But with 18 AWG solid copper conductors, you get reliable voltage delivery to all devices. This is crucial in emergency scenarios where every second counts and every notification must go through.
It’s flexible enough to make turns through conduit and tight ceiling spaces, but still rugged enough to endure installation stress. The insulation and outer jacket are designed to resist cuts and nicks, making it safer to pull through walls and risers.
This is the key feature. The outer jacket is engineered to stop fire from traveling along the cable. That matters a lot when you’re cabling between floors. A poorly rated cable could turn into a fuse that helps a fire spread. Not this one.
Fire codes aren’t just about function; they’re also about documentation and inspection. Most 18/2 riser cables come with visible, printed ratings on the jacket, which helps during inspection. You won’t need to dig through specs to prove code compliance.
Whether it's a Notifier, Siemens, or Honeywell fire panel—or a full-blown addressable system—18/2 riser cables play nice. That means fewer headaches during integration.
The versatility of this cable makes it ideal for a variety of low-voltage installations in commercial spaces, such as:
Fire alarm initiation circuits (pull stations, smoke detectors)
Notification appliance circuits (horns, strobes, speakers)
Intercom systems
Access control wiring
Security system sensors
You might be wondering: “Why not just use 16/2 cable?” or “What about plenum cable?” Let’s lay out the differences.
Feature | 18/2 Riser Cable | 16/2 Riser Cable | 18/2 Plenum Cable |
---|---|---|---|
Wire Gauge | Thinner (18 AWG) | Thicker (16 AWG) | Same as 18/2 |
Flexibility | More flexible | Less flexible | More flexible |
Fire Rating | Riser-rated | Riser-rated | Plenum-rated |
Cost | Moderate | Slightly higher | Higher |
Best Use Case | Floor-to-floor wiring | Long distances, high load | Air return spaces |
The bottom line? Use 18/2 riser cable when you need dependable, vertical fire alarm wiring and don’t want to overspend or over-engineer.
Using the right cable is only half the job. Installing it right seals the deal. Here are a few pro tips:
Don’t kink the cable. Follow the manufacturer’s bend radius guidelines to maintain signal quality and avoid jacket damage.
Twisting bare wires together with wire nuts might be fine for home use, but not for commercial-grade systems. Use proper terminal blocks or crimp connectors.
This isn’t just good practice—it could be code-required, depending on your region. Labeled cabling helps during maintenance and inspections.
Just because it's rated for up to 300 volts doesn’t mean it should handle high current. Stick to fire alarm devices within spec.
Always confirm that your cable selection and routing are compliant with local fire codes. Some cities require plenum cable even in vertical runs.
Q: Can I use 18/2 riser cable in plenum spaces?
A: No. Plenum-rated cable is required for air return spaces. Use FPLP or CL3P instead.
Q: What’s the maximum run length for 18/2 cable?
A: Depends on the device and current draw, but usually around 200 feet before you risk voltage drop.
Q: Is solid copper better than stranded for fire alarms?
A: For most commercial fire systems, solid copper is preferred—it offers better performance in permanent installations.
Here’s the thing: fire systems are a zero-fail zone. You don’t want mystery wires or shortcuts in your vertical cabling. The 18/2 Fire Alarm Riser Cable gives you exactly what you need—compliance, safety, and performance—without unnecessary extras that drive up cost or complexity.
In commercial buildings where vertical wiring is a given, this cable is a no-brainer. It holds up under pressure, passes inspections, and most importantly, helps keep people safe.
If you’re planning a new install or upgrading an existing system, 18/2 riser cable deserves a spot on your materials list. No gimmicks—just proven, code-aligned reliability.